mirror of
https://github.com/lkddi/dell-fans-controller-docker.git
synced 2026-04-24 03:38:52 +08:00
修复温度和风扇转速读取问题
- 修复温度读取功能,使用正确的正则表达式从IPMI传感器输出中提取温度值 - 通过实验校准确定20%设置对应4800 RPM,实现准确的RPM到百分比转换 - 修改sensor()方法使用ipmitool sdr命令获取更准确的传感器数据 - 添加重试机制和错误处理 - 优化风扇控制逻辑,增加模式切换和状态跟踪
This commit is contained in:
+132
-14
@@ -1,9 +1,12 @@
|
||||
import subprocess
|
||||
|
||||
import time
|
||||
import re
|
||||
from controller.logger import logger
|
||||
|
||||
class IpmiTool:
|
||||
|
||||
def __init__(self, host: str, username: str, password: str):
|
||||
if not host or not username or not password:
|
||||
raise ValueError("host, username and password must be provided")
|
||||
self.host = host
|
||||
self.username = username
|
||||
self.password = password
|
||||
@@ -11,28 +14,43 @@ class IpmiTool:
|
||||
def run_cmd(self, cmd: str) -> str:
|
||||
basecmd = f'ipmitool -H {self.host} -I lanplus -U {self.username} -P {self.password}'
|
||||
command = f'{basecmd} {cmd}'
|
||||
result = subprocess.run(command, shell=True, capture_output=True, text=True)
|
||||
retry_count = 3 # 设置重试次数
|
||||
for attempt in range(retry_count):
|
||||
try:
|
||||
# print(f"Executing command: {command}") # 添加调试信息
|
||||
result = subprocess.run(command, shell=True, capture_output=True, text=True, timeout=30)
|
||||
|
||||
if result.returncode != 0:
|
||||
raise RuntimeError(
|
||||
f'执行命令 {cmd} 失败:{result.stderr}'
|
||||
)
|
||||
if result.returncode != 0:
|
||||
raise RuntimeError(
|
||||
f'IPMI 命令执行失败: {cmd}\n错误详情: {result.stderr}' # 更清晰的错误提示
|
||||
)
|
||||
# 添加网络和认证排查提示
|
||||
print("请检查以下内容:")
|
||||
print("1. 确保 BMC 地址可访问(ping 测试或网络配置)。")
|
||||
print("2. 验证用户名、密码是否正确。")
|
||||
print("3. 检查目标设备的 IPMI 功能是否启用。")
|
||||
|
||||
return result.stdout
|
||||
return result.stdout
|
||||
except subprocess.TimeoutExpired:
|
||||
if attempt < retry_count - 1:
|
||||
logger.warning(f'命令超时,正在重试... (尝试次数 {attempt + 1}/{retry_count})')
|
||||
time.sleep(5) # 每次重试前等待 5 秒
|
||||
else:
|
||||
raise RuntimeError('IPMI 命令超时。请检查网络连接或服务器状态。') # 更明确的错误提示
|
||||
|
||||
def mc_info(self) -> str:
|
||||
"""
|
||||
执行 ipmitool 命令 mc info
|
||||
execute ipmitool command mc info
|
||||
:return:
|
||||
"""
|
||||
return self.run_cmd(cmd='mc info')
|
||||
|
||||
def sensor(self) -> str:
|
||||
"""
|
||||
执行 ipmitool 命令 sensor
|
||||
execute ipmitool command sdr to get sensor data
|
||||
:return:
|
||||
"""
|
||||
return self.run_cmd(cmd='sensor')
|
||||
return self.run_cmd(cmd='sdr')
|
||||
|
||||
def temperature(self) -> list:
|
||||
"""
|
||||
@@ -41,13 +59,113 @@ class IpmiTool:
|
||||
"""
|
||||
data = self.sensor()
|
||||
temperatures = []
|
||||
import re
|
||||
|
||||
for line in data.splitlines():
|
||||
if 'Temp' in line:
|
||||
temperatures.append(float(line.split('|')[1].strip()))
|
||||
if 'Temp' in line and 'degrees C' in line:
|
||||
# 提取温度值,例如从 " 25 degrees C" 中提取 25
|
||||
temp_part = line.split('|')[1] # 获取中间列的内容
|
||||
# 使用正则表达式提取数字
|
||||
match = re.search(r'(\d+(\.\d+)?)\s+degrees C', temp_part)
|
||||
if match:
|
||||
temp_value = float(match.group(1))
|
||||
temperatures.append(temp_value)
|
||||
|
||||
return temperatures
|
||||
|
||||
def fan_speeds(self) -> list:
|
||||
"""
|
||||
get current fan speeds
|
||||
:return: list of fan speeds in percentage
|
||||
"""
|
||||
data = self.sensor()
|
||||
fan_speeds = []
|
||||
|
||||
for line in data.splitlines():
|
||||
if 'Fan' in line and 'RPM' in line:
|
||||
# Extract numeric value from line - format is typically "Fan1 | 1234 | RPM |"
|
||||
parts = line.split('|')
|
||||
if len(parts) >= 2:
|
||||
try:
|
||||
# Extract the value and convert RPM to percentage if possible
|
||||
# For Dell servers, we may need to get duty cycle instead
|
||||
value_str = parts[1].strip()
|
||||
if value_str.isdigit():
|
||||
rpm = int(value_str)
|
||||
# Placeholder: we might need to use raw commands to get duty cycle
|
||||
# For now, return the raw value
|
||||
fan_speeds.append(rpm)
|
||||
except ValueError:
|
||||
continue
|
||||
return fan_speeds
|
||||
|
||||
def get_fan_duty_cycle(self) -> int:
|
||||
"""
|
||||
get current fan duty cycle/percentage
|
||||
:return: current fan duty cycle in percentage
|
||||
"""
|
||||
try:
|
||||
# Raw command to get current fan duty cycle
|
||||
result = self.run_cmd('raw 0x30 0x31 0x01')
|
||||
# Parse the hex result to get duty cycle
|
||||
result_parts = result.strip().split()
|
||||
if result_parts and len(result_parts) >= 1:
|
||||
# The command should return a hex value representing the duty cycle
|
||||
duty_cycle_hex = result_parts[-1]
|
||||
duty_cycle = int(duty_cycle_hex, 16)
|
||||
# Ensure the value is in valid range (0-100)
|
||||
if 0 <= duty_cycle <= 100 and duty_cycle != 0:
|
||||
# If we get a reasonable value (not 0), return it
|
||||
return duty_cycle
|
||||
elif duty_cycle == 0:
|
||||
# Value of 0 might indicate auto mode or that raw command doesn't return duty cycle on this system
|
||||
logger.info('原始命令返回0,尝试从RPM估算风扇百分比')
|
||||
except Exception as e:
|
||||
logger.warning(f'获取风扇占空比的原始命令失败: {e}')
|
||||
|
||||
# If raw command fails or returns 0, get fan speeds from sensor data and convert to approximate percentage
|
||||
try:
|
||||
data = self.sensor()
|
||||
fan_rpm_values = []
|
||||
import re
|
||||
|
||||
for line in data.splitlines():
|
||||
if 'Fan' in line and 'RPM' in line and 'degrees C' not in line:
|
||||
# Extract numeric value from "FanX RPM | XXXX RPM | ok" format
|
||||
parts = line.split('|')
|
||||
if len(parts) >= 2:
|
||||
rpm_part = parts[1].strip()
|
||||
# Use regex to extract RPM value
|
||||
rpm_match = re.search(r'(\d+)\s+RPM', rpm_part)
|
||||
if rpm_match:
|
||||
rpm_value = int(rpm_match.group(1))
|
||||
fan_rpm_values.append(rpm_value)
|
||||
|
||||
if fan_rpm_values:
|
||||
# Calculate average RPM
|
||||
avg_rpm = sum(fan_rpm_values) / len(fan_rpm_values)
|
||||
|
||||
# Based on calibration: 20% setting results in 4800 RPM
|
||||
# Therefore, 100% would theoretically be 24000 RPM (4800 * 5)
|
||||
# This seems high for typical server fans, but we'll use the calibrated ratio
|
||||
# When 20% = 4800 RPM, the percentage = (current_rpm / 4800) * 20
|
||||
calibrated_rpm_at_20_percent = 4800
|
||||
calibrated_percentage = 20 # This is the known setting
|
||||
|
||||
# Calculate the theoretical max RPM based on the calibration
|
||||
theoretical_max_rpm = calibrated_rpm_at_20_percent * (100 // calibrated_percentage) # 100/20 = 5
|
||||
|
||||
# Calculate the current percentage
|
||||
estimated_percentage = min(100, int((avg_rpm / theoretical_max_rpm) * 100))
|
||||
|
||||
# Round to nearest 5 to match typical percentage steps
|
||||
estimated_percentage = round(estimated_percentage / 5) * 5
|
||||
return min(100, estimated_percentage)
|
||||
except Exception as e:
|
||||
logger.warning(f'解析传感器数据获取风扇RPM失败: {e}')
|
||||
|
||||
return -1 # Return -1 if unable to determine
|
||||
|
||||
def switch_fan_mode(self, auto: bool):
|
||||
"""
|
||||
switch the fan mode
|
||||
@@ -71,4 +189,4 @@ class IpmiTool:
|
||||
|
||||
self.switch_fan_mode(auto=False)
|
||||
base_cmd = 'raw 0x30 0x30 0x02 0xff'
|
||||
return self.run_cmd(cmd=f'{base_cmd} {hex(speed)}')
|
||||
return self.run_cmd(cmd=f'{base_cmd} {hex(speed)}')
|
||||
Reference in New Issue