mirror of
https://github.com/lkddi/dell-fans-controller-docker.git
synced 2026-05-18 21:57:29 +08:00
优化IPMI失败冷却和手动模式切换
This commit is contained in:
@@ -1,4 +1,5 @@
|
||||
import unittest
|
||||
from unittest.mock import Mock
|
||||
|
||||
from controller.client import FanController
|
||||
|
||||
@@ -54,6 +55,16 @@ class FanControllerConfigTest(unittest.TestCase):
|
||||
|
||||
self.assertFalse(controller.use_raw_fan_duty)
|
||||
|
||||
def test_set_fan_speed_switches_manual_mode_only_once(self):
|
||||
controller = self.make_controller()
|
||||
controller.ipmi = Mock()
|
||||
|
||||
controller.set_fan_speed(30)
|
||||
controller.set_fan_speed(40)
|
||||
|
||||
controller.ipmi.switch_fan_mode.assert_called_once_with(auto=False)
|
||||
self.assertEqual(controller.ipmi.set_fan_speed.call_count, 2)
|
||||
|
||||
|
||||
if __name__ == '__main__':
|
||||
unittest.main()
|
||||
|
||||
Reference in New Issue